== What You'll Need == | == What You'll Need == | ||
Before heading out to test, ensure that you have the following pieces of equipment: <br> | Before heading out to test, ensure that you have the following pieces of equipment: <br> | ||
− | 1) '''Transmit/receive [[OpComms System IV|node]].''' | + | 1) '''Transmit/receive [[OpComms System IV|node]].''' Ensure that the laser, photodetector, control board, and BNC connection between sensor and board are all present. <br> |
− | 2) '''Tripod.''' | + | 2) '''Tripod.''' Make sure the tripod matches the node you have chosen. The Rosencrantz tripod has a round plate with a hole in the center; the Guildenstern tripod has a large tri-lobed plate that is continuous. <br> |
− | 3) '''Laptop.''' Ensure your code is up to date by pulling from the OpComms Github repository. | + | 3) '''Laptop.''' Ensure your code is up to date by pulling from the OpComms Github repository. <br> |
− | 4) '''Keysight oscilloscope.''' Have Sasha or Elizabeth unlock an oscilloscope from the toolbox. | + | 4) '''Keysight oscilloscope.''' Have Sasha or Elizabeth unlock an oscilloscope from the toolbox. Guard it with your life. <br> |
− | 5) '''Test bin.''' Must contain toolbox, extension cords, power supplies, and motorized alt/az mount. | + | 5) '''Test bin.''' Must contain toolbox, extension cords, power supplies, and motorized alt/az mount. Use a dry-erase marker to complete the Test Checklist posted on the lid of the bin. If all of the contents are present you may proceed <br> |
== Set Up == | == Set Up == | ||
− | '''Step 1:''' Set up tripod on a piece of level ground. | + | '''Step 1:''' Set up tripod on a piece of level ground. Attempt to identify the approximate location of the communicating node and ensure you have a clear line of sight in that direction. <br> |
− | '''Step 2:''' Find a source of AC power and run an extension cord to your test site. | + | '''Step 2:''' Find a source of AC power and run an extension cord to your test site. Verify you have at least 2 outlets available, using a power strip if necessary. <br> |
− | '''Step 3:''' Attach motorized alt/az mount. | + | '''Step 3:''' Attach motorized alt/az mount. Use the attached mounting hardware to screw through the tripod plate and into the bottom of the mount. Ensure that the mount is solidly attached. If you are using the Guildenstern tripod, make sure that all three feet on the base of the mount are in contact with the surface of the tripod plate (if not, rotate). <br> |
− | '''Step 4:''' Find the leather battery purse and plug it into the mount. | + | '''Step 4:''' Find the leather battery purse and plug it into the mount. Verify that all batteries (AA) are present and replace if missing. Hang or support the purse somewhere on the tripod. |
− | '''Step 5:''' Attach the transmit/receive node to the mount by sliding the black plastic adapter on the node into the mount's slot. | + | '''Step 5:''' Attach the transmit/receive node to the mount by sliding the black plastic adapter on the node into the mount's slot. Make sure that the angled and flat faces are oriented correctly and that the adapter block slides fully into the slot. Tighten the set screw on the mount, ensuring a firm connection (although do not overtighten, as the screw is bearing on plastic). <br> |
'''Step 6:''' Find the modular cable (phone jack) in the yellow toolbox and connect it between the mount and the control board. <br> | '''Step 6:''' Find the modular cable (phone jack) in the yellow toolbox and connect it between the mount and the control board. <br> | ||
− | '''Step 7:''' Find the photodetector's power supply in the test bin (2 parts: one large block that plugs into AC + one 3-pin cable that connects to the block). | + | '''Step 7:''' Find the photodetector's power supply in the test bin (2 parts: one large block that plugs into AC + one 3-pin cable that connects to the block). Plug one side into AC. Plug the other side into the unoccupied port on the sensor, by first aligning the pins, pressing firmly, and screwing down the retaining collar. Make sure the switch on the power supply block is switched on, and verify that the sensor has power (check for green light between power and BNC ports on the top face of the sensor). <br> |
− | '''Step 8:''' Set up and plug in the Keysight oscilloscope. | + | '''Step 8:''' Set up and plug in the Keysight oscilloscope. The power cable can be found in the side pouch inside the main compartment of the Keysight case. Toggle the power switch to start the boot sequence. Find the BNC cable in the yellow toolbox and connect the downward-facing BNC port on the control board to Source 1 on the oscilloscope. Adjust the vertical scaling to 20mV/division and the horizontal scaling to 10us/division. <br> |
− | '''Step 9:''' Find the microUSB cable in the yellow toolbox and connect the control board to a USB port on your computer. | + | '''Step 9:''' Find the microUSB cable in the yellow toolbox and connect the control board to a USB port on your computer. Open Arduino and connect to the board (Teensy 3.1), ensuring that a serial port appears in the Tools menu. Upload the code to the board and open the serial monitor when this is complete. <br> |
'''Step 10:''' Remove the lens cap from the node and ensure that the switch cover on the laser is flipped such that the button is continuously depressed. <br> | '''Step 10:''' Remove the lens cap from the node and ensure that the switch cover on the laser is flipped such that the button is continuously depressed. <br> | ||
+ | '''Step 11:''' Straighten up the area. Close the toolbox and store it in the test bin. Place the test bin and oscilloscope case underneath of the tripod. <br> | ||
<br> | <br> | ||
− | You're done! | + | ''You're done! Let's test!'' |
==Test== | ==Test== | ||
==Pack Up== | ==Pack Up== | ||
+ | In general, store cables wrapped and secured with twist ties. Any component with a labeled place in the toolbox should return there. | ||
+ | |||
+ | '''Step 1:''' Place the lens cap on the transmit/receive node and ensure the clips lock it into place. <br> | ||
+ | '''Step 2:''' Turn off oscilloscope and unplug it. Pack the BNC Cable back into the yellow toolbox. Disconnect the power cable from the oscilloscope and pack it into the side pouch in the Keysight case. Snap the front cover onto the oscilloscope and zip it and the side pouch inside the carrying case. <br> | ||
+ | '''Step 3:''' Disconnect your computer and store the MicroUSB cable in the yellow toolbox. <br> | ||
+ | '''Step 4:''' Switch off and disconnect the photodetector's power supply. Store in the test bin. <br> | ||
+ | '''Step 5:''' Disconnect the modular cable (phone jack) and store in the yellow toolbox. <br> | ||
+ | '''Step 6:''' Disconnect the mount's battery purse and store in the test bin. <br> | ||
+ | '''Step 7:''' Hold the transmit/receive node firmly and loosen the set screw to remove from the mount. Leave the sensor BNC cable and laser power wires connected. <br> | ||
+ | '''Step 8:''' Unscrew the motorized mount from the tripod plate. Make sure to screw the mounting hardware back onto the bottom of the mount for storage. Store in the test bin. <br> | ||
+ | '''Step 9:''' Collapse tripod. <br> | ||
+ | '''Step 10:''' Check the area for forgotten components. Ensure you have the test bin (with toolbox), transmit/receive node, laptop, oscilloscope, and tripod. <br> | ||
+ | <br> | ||
+ | ''Head home. If you're driving back from Skyline Boulevard, you probably want to stop at Secret Safeway and get some ice cream :)'' | ||
+ | |||
+ | == Back Home == | ||
+ | Upload your photos and data to Google Drive, in a folder with today's date and the test location. You'll also probably want to debrief to interpret test results and figure out next steps. If the test was significant, write a blog post about it. | ||
[[Category:Optical Communications]] | [[Category:Optical Communications]] |
Revision as of 21:08, 5 February 2016
What follows is a complete set of instructions for completing a long-distance test (of any length) with the current Optical Communications transmitter/receiver node system.
What You'll Need
Before heading out to test, ensure that you have the following pieces of equipment:
1) Transmit/receive node. Ensure that the laser, photodetector, control board, and BNC connection between sensor and board are all present.
2) Tripod. Make sure the tripod matches the node you have chosen. The Rosencrantz tripod has a round plate with a hole in the center; the Guildenstern tripod has a large tri-lobed plate that is continuous.
3) Laptop. Ensure your code is up to date by pulling from the OpComms Github repository.
4) Keysight oscilloscope. Have Sasha or Elizabeth unlock an oscilloscope from the toolbox. Guard it with your life.
5) Test bin. Must contain toolbox, extension cords, power supplies, and motorized alt/az mount. Use a dry-erase marker to complete the Test Checklist posted on the lid of the bin. If all of the contents are present you may proceed
Set Up
Step 1: Set up tripod on a piece of level ground. Attempt to identify the approximate location of the communicating node and ensure you have a clear line of sight in that direction.
Step 2: Find a source of AC power and run an extension cord to your test site. Verify you have at least 2 outlets available, using a power strip if necessary.
Step 3: Attach motorized alt/az mount. Use the attached mounting hardware to screw through the tripod plate and into the bottom of the mount. Ensure that the mount is solidly attached. If you are using the Guildenstern tripod, make sure that all three feet on the base of the mount are in contact with the surface of the tripod plate (if not, rotate).
Step 4: Find the leather battery purse and plug it into the mount. Verify that all batteries (AA) are present and replace if missing. Hang or support the purse somewhere on the tripod.
Step 5: Attach the transmit/receive node to the mount by sliding the black plastic adapter on the node into the mount's slot. Make sure that the angled and flat faces are oriented correctly and that the adapter block slides fully into the slot. Tighten the set screw on the mount, ensuring a firm connection (although do not overtighten, as the screw is bearing on plastic).
Step 6: Find the modular cable (phone jack) in the yellow toolbox and connect it between the mount and the control board.
Step 7: Find the photodetector's power supply in the test bin (2 parts: one large block that plugs into AC + one 3-pin cable that connects to the block). Plug one side into AC. Plug the other side into the unoccupied port on the sensor, by first aligning the pins, pressing firmly, and screwing down the retaining collar. Make sure the switch on the power supply block is switched on, and verify that the sensor has power (check for green light between power and BNC ports on the top face of the sensor).
Step 8: Set up and plug in the Keysight oscilloscope. The power cable can be found in the side pouch inside the main compartment of the Keysight case. Toggle the power switch to start the boot sequence. Find the BNC cable in the yellow toolbox and connect the downward-facing BNC port on the control board to Source 1 on the oscilloscope. Adjust the vertical scaling to 20mV/division and the horizontal scaling to 10us/division.
Step 9: Find the microUSB cable in the yellow toolbox and connect the control board to a USB port on your computer. Open Arduino and connect to the board (Teensy 3.1), ensuring that a serial port appears in the Tools menu. Upload the code to the board and open the serial monitor when this is complete.
Step 10: Remove the lens cap from the node and ensure that the switch cover on the laser is flipped such that the button is continuously depressed.
Step 11: Straighten up the area. Close the toolbox and store it in the test bin. Place the test bin and oscilloscope case underneath of the tripod.
You're done! Let's test!
Test
Pack Up
In general, store cables wrapped and secured with twist ties. Any component with a labeled place in the toolbox should return there.
Step 1: Place the lens cap on the transmit/receive node and ensure the clips lock it into place.
Step 2: Turn off oscilloscope and unplug it. Pack the BNC Cable back into the yellow toolbox. Disconnect the power cable from the oscilloscope and pack it into the side pouch in the Keysight case. Snap the front cover onto the oscilloscope and zip it and the side pouch inside the carrying case.
Step 3: Disconnect your computer and store the MicroUSB cable in the yellow toolbox.
Step 4: Switch off and disconnect the photodetector's power supply. Store in the test bin.
Step 5: Disconnect the modular cable (phone jack) and store in the yellow toolbox.
Step 6: Disconnect the mount's battery purse and store in the test bin.
Step 7: Hold the transmit/receive node firmly and loosen the set screw to remove from the mount. Leave the sensor BNC cable and laser power wires connected.
Step 8: Unscrew the motorized mount from the tripod plate. Make sure to screw the mounting hardware back onto the bottom of the mount for storage. Store in the test bin.
Step 9: Collapse tripod.
Step 10: Check the area for forgotten components. Ensure you have the test bin (with toolbox), transmit/receive node, laptop, oscilloscope, and tripod.
Head home. If you're driving back from Skyline Boulevard, you probably want to stop at Secret Safeway and get some ice cream :)
Back Home
Upload your photos and data to Google Drive, in a folder with today's date and the test location. You'll also probably want to debrief to interpret test results and figure out next steps. If the test was significant, write a blog post about it.