|These pins, although on the databus, provide 12V power for 12V applications -- when used, all four nets should be connected together and used in parallel.
+
|NO
+
|-
+
|113, 114
+
|+5V and -5V (signal applications)
+
|These pins are meant to be used for signal applications requiring a dual polarity +5V to -5V rail-to-rail supply. They only put out 15 mA, and should not be used for any power applications whatsoever.
+
|NO
+
|-
+
|115, 116
+
|+12V and -12V (signal applications)
+
|These pins are meant to be used for signal applications requiring a dual polarity +12V to -12V rail-to-rail supply. They only put out 15 mA, and should not be used for any power applications whatsoever.
+
|NO
+
|-
+
|37, 42-111, 117-120
|NC
|NC
|Reserved -- these can be used for any purpose at the time being, as long as it is agreed in advance.
|Reserved -- these can be used for any purpose at the time being, as long as it is agreed in advance.