Difference between revisions of "Project UV"
(19 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | Project UV is the 2015-2016 Balloons | + | Project UV is the 2015-2016 Balloons team project to develop effective countermeasures against the UV degradation of latex balloons, in order to increase the potential flight time of future payloads. |
+ | |||
+ | The current team leads are [[User:dragland|Davy Ragland]] and Yuji Sugimoto. | ||
+ | |||
+ | == Chemical protection== | ||
+ | [[File:SSI_UV_00.png | right | thumb| <center> Preliminary data</center>]] | ||
+ | Because ultra violet radiation physically degrades the polymers within the latex, a chemical solution may elongate its lifespan. | ||
+ | A preliminary test was done with a set of various chemical coatings, balloon types, and strech values. However, the test had to be stopped for winter break, so the degradation point of some samples could only be predicted, not verified. Nevertheless, the initial results seem optimistic. While the sunscreen made the latex brittle, the Anti-UV Scuba spray seemed to elongate the lifespan. | ||
+ | |||
+ | == SSI-28 == | ||
+ | [[File:SSI_28_09.png | left | thumb| <center> SSI-28 data</center>]] | ||
+ | [[File:SSI_UV_01.png | left | thumb| <center> Averaged SSI-28 data</center>]] | ||
+ | [[File:SSI_28_10.png | left | thumb| <center> SSI-28 data</center>]] | ||
+ | [[File:SSI_UV_02.png | left | thumb| <center> Averaged SSI-28 data</center>]] | ||
+ | In order understand the exact effect of ultra violet A and B present at different altitudes, a sensor for each UV type was launched on the [[SSI-28]] launch. From the collected data, it can be concluded that there is much more UV A than UV B, and it does in fact increase with altitude, reaching a max value of 1323 microwatts/cm^2 for UV A and 292 microwatts/cm^2 for UV B. In addition, there was a lot of oscillation in values, which is due to the sensor being on one side, and the payload spinning during its flight. Thus, the value where the sun is directly facing the latex would correspond to the high part of the wave. | ||
+ | |||
+ | == SSI-30 == | ||
+ | From [[SSI-28]], we learned that the sensor value fluctuates with the orientation of the payload, so a second flight was conducted on [[SSI-30]] with the UV A and UV B sensors, combined with a 10DOF acceleration and orientation sensor. Trough this sensor fusion, the high points of the microWats/cm^2 crest can be correlated the direct illumination of the sun, giving us a more accurate UV value than a simple average, and we will also gain a good understanding of the levels of ambient UV scattering at specific altitudes. This flight also served to validate the data from the previous launch, so that we can account for the effect of atmospheric differences. | ||
+ | |||
+ | == Chemical concentration== | ||
+ | As result of the positive results of the chemical protection tests, and the new UV intensity data from [[SSI-28]], a new experiment will be done indoors with UV LEDs that emit light at 365 manometers at a constant intencity. This will be to control for and calculate the exact amount of UV that the latex is being exposed to, in order to determine the proportion of UV concentration to natural sunlight at the desired altitude. The independent variable will be the concentration of chemical spray per area, which will be tested against the independent variable of lifespan, in order determine the ideal amount of Anti-UV Scuba spray to apply onto the balloon. | ||
+ | |||
+ | == Chemical application== | ||
+ | Once the ideal concentration of protective chemicals per surface area is determined, an effective method of application will be developed, in order to ensure that the right amount of chemicals are placed on the right area. Current ideas include converting it into an aerosol or soaking the balloon. | ||
+ | |||
+ | == Gallery == | ||
+ | <gallery widths=300px heights=300px> | ||
+ | File:SSI_UV_00.png | <center> Project UV data</center> | ||
+ | File:SSI_28_09.png | <center> Project UV data</center> | ||
+ | File:SSI_28_10.png | <center> Project UV data</center> | ||
+ | File:SSI_UV_01.png | <center> Project UV data</center> | ||
+ | File:SSI_UV_02.png | <center> Project UV data</center> | ||
+ | </gallery> | ||
+ | |||
{{balloon-footer}} | {{balloon-footer}} | ||
[[Category: High Altitude Balloons]][[Category: Projects]] | [[Category: High Altitude Balloons]][[Category: Projects]] |
Latest revision as of 06:48, 16 February 2016
Project UV is the 2015-2016 Balloons team project to develop effective countermeasures against the UV degradation of latex balloons, in order to increase the potential flight time of future payloads.
The current team leads are Davy Ragland and Yuji Sugimoto.
Chemical protection
Because ultra violet radiation physically degrades the polymers within the latex, a chemical solution may elongate its lifespan. A preliminary test was done with a set of various chemical coatings, balloon types, and strech values. However, the test had to be stopped for winter break, so the degradation point of some samples could only be predicted, not verified. Nevertheless, the initial results seem optimistic. While the sunscreen made the latex brittle, the Anti-UV Scuba spray seemed to elongate the lifespan.
SSI-28
In order understand the exact effect of ultra violet A and B present at different altitudes, a sensor for each UV type was launched on the SSI-28 launch. From the collected data, it can be concluded that there is much more UV A than UV B, and it does in fact increase with altitude, reaching a max value of 1323 microwatts/cm^2 for UV A and 292 microwatts/cm^2 for UV B. In addition, there was a lot of oscillation in values, which is due to the sensor being on one side, and the payload spinning during its flight. Thus, the value where the sun is directly facing the latex would correspond to the high part of the wave.
SSI-30
From SSI-28, we learned that the sensor value fluctuates with the orientation of the payload, so a second flight was conducted on SSI-30 with the UV A and UV B sensors, combined with a 10DOF acceleration and orientation sensor. Trough this sensor fusion, the high points of the microWats/cm^2 crest can be correlated the direct illumination of the sun, giving us a more accurate UV value than a simple average, and we will also gain a good understanding of the levels of ambient UV scattering at specific altitudes. This flight also served to validate the data from the previous launch, so that we can account for the effect of atmospheric differences.
Chemical concentration
As result of the positive results of the chemical protection tests, and the new UV intensity data from SSI-28, a new experiment will be done indoors with UV LEDs that emit light at 365 manometers at a constant intencity. This will be to control for and calculate the exact amount of UV that the latex is being exposed to, in order to determine the proportion of UV concentration to natural sunlight at the desired altitude. The independent variable will be the concentration of chemical spray per area, which will be tested against the independent variable of lifespan, in order determine the ideal amount of Anti-UV Scuba spray to apply onto the balloon.
Chemical application
Once the ideal concentration of protective chemicals per surface area is determined, an effective method of application will be developed, in order to ensure that the right amount of chemicals are placed on the right area. Current ideas include converting it into an aerosol or soaking the balloon.