Difference between revisions of "Project UV"

From Stanford SSI Wiki
Jump to navigation Jump to search
Line 4: Line 4:
  
 
== Chemical protection==
 
== Chemical protection==
[[File:SSI_UV_00.png | left | thumb| <center> Preliminary data</center>]]
+
[[File:SSI_UV_00.png | right | thumb| <center> Preliminary data</center>]]
 
Because ultra violet radiation physically degrades the polymers within the latex, a chemical solution may elongate its lifespan.
 
Because ultra violet radiation physically degrades the polymers within the latex, a chemical solution may elongate its lifespan.
 
A preliminary test was done with a set of various chemical coatings, balloon types, and strech values. However, the test had to be stopped for winter break, so the degradation point of some samples could only be predicted, not verified. Nevertheless, the initial results seem optimistic.   
 
A preliminary test was done with a set of various chemical coatings, balloon types, and strech values. However, the test had to be stopped for winter break, so the degradation point of some samples could only be predicted, not verified. Nevertheless, the initial results seem optimistic.   

Revision as of 08:06, 1 February 2016

Project UV is the 2015-2016 Balloons team project to develop effective countermeasures against the UV degradation of latex balloons, in order to increase the potential flight time of future payloads.

The current team leads are Davy Ragland and Yuji Sugimoto.

Chemical protection

Preliminary data

Because ultra violet radiation physically degrades the polymers within the latex, a chemical solution may elongate its lifespan. A preliminary test was done with a set of various chemical coatings, balloon types, and strech values. However, the test had to be stopped for winter break, so the degradation point of some samples could only be predicted, not verified. Nevertheless, the initial results seem optimistic.

SSI-28

SSI-28 data
SSI-28 data

In order to collect data on the levels of ultra violet A and B present at different altitudes, a sensor for each UV type was launched on SSI-28. From the data, it can be concluded that there is much more UV A than UV B, and it does in fact increase with altitude, reaching a max value of 1323 microwatts/cm^2 for UV A and 292 microwatts/cm^2 for UV B. In addition, there is a lot of noise in the values, with a corresponding oscillation of values, which is due to the sensor being on one side, and the payload spinning during its flight. Thus, the value where the sun is directly facing the latex would correspond to the high part of the wave.

Chemical concentration

As result of the positive results of the chemical protection tests, a new experiment will be done indoors with UV LEDs that emit light at 365 manometers. This will be to control for and calculate the exact amount of UV that the latex is being exposed to. The UC sensors will be used to determine the proportion of UV concentration to natural sunlight at the desired altitude. The independent variable will be the concentration of chemical spray per area, in order determine the ideal amount to apply onto the balloon.

Gallery

Balloon Launches
2014-15 SSI-19202122
2015-16 SSI-23(a) • 2425262728293031323334353637383940414243
2016-17 444546474849505152
2017-18
2018-19 8386879091
2019-20 929397
VE